Noise audit of device selection for peripheral vascular interventions in the Vascular Quality Initiative
William K Robinson1, Peter W Callas2, Jens Eldrup-Jorgensen3
1Department of Surgery, Tufts Medical Center, Boston, MA.
Objective:
To conduct a noise audit of the Vascular Quality Initiative (VQI) Peripheral Vascular Intervention (PVI) Registry to analyze variation in device selection for similar patients and anatomies.
Methods:
We conducted a retrospective cohort study analysis of the VQI PVI Registry. Eight clinical-based and seven lesion-based scenarios were developed, and the VQI was queried for all procedures matching these descriptions from December 2010 to December 2021. All patients undergoing PVI for either claudication or chronic limb-threatening ischemia were included. Device selection was then identified for each procedure, with a treatment hierarchy to designate the primary device class along with a separate accounting of specialty balloons, including drug-coated and lithoplasty devices. Variability was then quantified in each mock patient scenario using the most commonly used device as the reference standard.
Results:
The number of patients matching the criteria for each mock scenario ranged from 223 to 1379 across 8 clinical and from 6166 to 26,241 in 7 lesion-based scenarios. The most commonly used device in a given patient scenario was used between 32% and 72% of procedures in the clinical based scenarios, and between 34% and 67% of procedures in the lesion-based scenarios. Variation in device selection and use of specialty balloons were found to be significant across all patient scenarios (P < .0001).
Conclusions:
Noise in PVI device selection and use of drug-coated balloons in the VQI was significant across 15 mock scenarios. This finding indicates that similar patients with similar vascular pathologies are receiving vastly different devices and confirms that future comparative effectiveness studies are required to combat this systemic source of noise in device selection more effectively.
More Related Videos
Related Concept Videos
Pulse Assessment Sites
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...