Related Experiment Video
Updated: Jun 1, 2025

Production and Analysis of Sporosarcina pasteurii Biocement Bricks Using Custom 3D-Printed Molds for Unconfined Compression Tests
Published on: March 7, 2025
Ecological concrete by partially substitution of cement with Cameroonian corn stover ash
Martial Ngnihamye Nde1,2, Seidou Youssoufa1,3, Fabien Kenmogne2,4
1Department of Civil Engineering, National Advanced School of Public Works, P.O. Box 510, Yaoundé, Cameroon.
Abstract:
This study focuses on the influence of the partial substitution of cement by Cameroonian corn stover ash (CCSA) on the physical and mechanical behavior of concrete. For this, as materials used, one has first the corn stovers coming from the Bandjoun town in the Koung-khi division, in the West region of Cameroon, which are used to obtain the ashes, while the sand used, came from the Sanaga River in the coastal region of Cameroon. In order to obtain the CCSA, the corn stover is calcined in an oven at 600 °C for 6 h and then characterized; the characterization included infrared spectrometry, X-ray fluorescence spectrometry, fineness of grinding, and absolute density. Four concrete formulations were prepared, according to the amount of CCSA (that is at 0 %, 5 %, 10 % and 15 %), in order to carry out tests in the fresh state (slump test, compactness) and in the hardened state, i.e. mechanical tests (compression and bending tests) and physical tests (density test, water absorption, and porosity) after 7, 14, 28 and 60 days. The results of the chemical analyses carried out on the CCSA show that it contains 73.97 % of SiO2 + Al2O3 + Fe2O3, giving it a pozzolanic character in accordance with ASTM C618 standard. The mechanical behavior at an early age (0-28 days) showed a general decrease in strength for concretes containing CCSA. Replacing 10 % of the cement with CCSA showed the best mechanical performance (compressive and flexural strength) in the long term (60 days) as compared to the control concrete (with 0 % of CCSA). At the same substitution rate the lower absorption and porosity rates were obtained, which are close to those of the control concrete, with relative differences of ±2.43 % and ±3.06 % respectively.
Related Concept Videos
Additives and Fillers in Concrete
The...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Pozzolans
Fly ash is...
Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Porosity in Cement Paste
The balance of water to cement in the mix is...

