Oxygen extraction fraction is not uniform in human brain: a positron emission tomography study
Hiroshi Ito1, Masanobu Ibaraki2, Ryo Yamakuni3
1Department of Radiology and Nuclear Medicine, Fukushima Medical University, 1 Hikariga-Oka, 960-1295, Fukushima, Japan; Advanced Clinical Research Center, Fukushima Medical University, Fukushima, Japan.
Abstract:
The regional differences in cerebral oxygen extraction fraction (OEF) in brain were investigated using positron emission tomography (PET) in detail with consideration of systemic errors in PET measurement estimated by simulation studies. The cerebral blood flow (CBF), cerebral blood volume (CBV), OEF, and cerebral metabolic rate of oxygen (CMRO2) were measured on healthy men by PET with 15O-labeled gases. The OEF values in the pons and the parahippocampal gyrus were significantly smaller than in the other brain regions. The OEF value in the lateral side of the occipital cortex was largest among the cerebral cortical regions. Simulation studies have revealed that errors in OEF caused by regional differences in the distribution volume of 15O-labeled water, as well as errors in OEF caused by a mixture of gray and white matter, must be negligible. The regional differences in OEF in brain must exist which might be related to physiological meanings.Article title: Kindly check and confirm the edit made in the article title.I have checked the article title and it is OK as is. Trial registration: The UMIN clinical trial number: UMIN000033382, https://www.umin.ac.jp/ctr/index.htm.
More Related Videos
09:07Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
07:28Studying Metabolic Brain Connectivity Using 2-Deoxy-2-[18F]Fluoro-D-Glucose Dynamic Positron Emission Tomography at the Single-subject Level
Published on: January 24, 2025
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET