Hydrogels are natural/synthetic polymer-based materials with a large percentage of water content, usually above 80 %, and are suitable for many application fields such as wearable sensors, biomedicine, cosmetics, agriculture, etc. However, their performance is susceptible to environmental changes in temperature, relative humidity, and mechanical deformation due to their aqueous and soft nature. We investigate the mechanical response of both filled and unfilled alginate/gellan hydrogels using a combined axial-torsional rheometric approach with cylindrical samples of large length/diameter ratio under controlled temperature and relative humidity. Dynamic Mechanical Analysis (DMA) is performed on the same specimen in both torsion and extension under identical experimental conditions. This rheometric approach ensures consistent initial and boundary conditions, which are essential for a reliable estimation of viscoelastic moduli G* and E*, and their dependence on temperature, frequency, and relative humidity. Our findings indicate that humidity critically affects the mechanical response of the material due to sample volume shrinkage, necessitating corrections to the viscoelastic moduli. We also find temperature plays a role only at low/medium relative humidity values. The inclusion of fillers leads to a modest increase in the elasticity of the hydrogel, probably due to restricted water diffusion out of the sample. In connection with the latest, unfilled samples in breaking tests present only slippage due to twist-induced surface water excess, opposite to breakage events shown by filled samples, probably linked to restricted water diffusion.
More Related Videos
12:22Synthesis of Thermogelling PolyN-isopropylacrylamide-graft-chondroitin Sulfate Composites with Alginate Microparticles for Tissue Engineering
Published on: October 26, 2016
16:20Bioprintable Alginate/Gelatin Hydrogel 3D In Vitro Model Systems Induce Cell Spheroid Formation
Published on: July 2, 2018
Related Concept Videos
Determining the pH of Salt Solutions
Potentiometry: Membrane Electrodes
Precipitation and Co-precipitation
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Automated Microbial Diagnostics