A noise-robust post-processing pipeline for accelerated phase-cycled 23Na Multi-Quantum Coherences MRI.
Christian Licht1, Efe Ilicak2, Fernando E Boada3
1Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany; Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany; Radiological Sciences Laboratory, School of Medicine, Stanford University, Stanford, California, USA.
This study introduces a new pipeline for sodium (23Na) Multi-Quantum Coherences (MQC) MRI, enhancing image quality and reducing scan times. The method improves signal-to-noise ratio and robustly separates signals for better brain imaging at 7 Tesla.
Area of Science:
- Medical Imaging
- Biophysics
- Neuroimaging
Background:
- Sodium (23Na) Multi-Quantum Coherences (MQC) MRI is valuable for in vivo human brain imaging at 7 Tesla.
- Current MQC MRI techniques face challenges with low signal-to-noise ratio (SNR) and lengthy radiofrequency (RF) phase-cycling.
- Accurate separation of Single Quantum (SQ) and Triple Quantum (TQ) signals is essential for calculating the TQ/SQ ratio, a key diagnostic parameter.
Purpose of the Study:
- To develop an advanced post-processing pipeline for noise-robust, accelerated 23Na MQC MRI of the in vivo human brain at 7 T.
- To enhance SNR and improve the separation of SQ and TQ signal components in 23Na MQC MRI.
- To reduce acquisition time while maintaining high image quality.
Main Methods:
- Combined low-rank k-space denoising for SNR enhancement with Dynamic Mode Decomposition (DMD) for robust SQ and TQ signal separation.
- Validated the pipeline in silico, in vitro, and in vivo, comparing it against conventional denoising and Fourier Transform (FT) methods.
- Assessed pipeline robustness using ablation experiments simulating corrupted RF phase-cycling steps.
Main Results:
- The denoising algorithm doubled SNR compared to non-denoised images and improved SNR by up to 29% over Wavelet denoising.
- DMD effectively separated SQ and TQ signals, even with incomplete RF phase-cycling, achieving superior SSIM (0.89±0.024) and lower RMSE (0.055±0.008) compared to FT methods.
- Enabled high-quality 8x8x15mm3 in vivo 23Na MQC MRI with acquisition time reduced from 48 to 10 minutes.
Conclusions:
- The proposed pipeline significantly enhances robustness in 23Na MQC MRI through low-rank denoising and DMD-based signal separation.
- Achieved high-quality MR images for both SQ and TQ components, even under accelerated and incomplete RF phase-cycling conditions.
- This method offers a more efficient and reliable approach for advanced 23Na MQC MRI of the human brain.
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
NMR Spectrometers: Resolution and Error Correction
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)