Related Experiment Video
Updated: Apr 6, 2026

Scanning Skeletal Remains for Bone Mineral Density in Forensic Contexts
Published on: January 29, 2018
Bone imaging modality precision and agreement between DXA, pQCT, and HR-pQCT
Jakub Mesinovic1,2, Mícheál Ó Breasail2,3, Lauren A Burt4
1Institute for Physical Activity and Nutrition (IPAN), School of Exercise and Nutrition Sciences, Deakin University, Burwood, VIC 3125, Australia.
Abstract:
Quantifying precision error for DXA, peripheral QCT (pQCT), and HR-pQCT is crucial for monitoring longitudinal changes in body composition and musculoskeletal outcomes. Agreement and associations between bone variables assessed using pQCT and second-generation HR-pQCT are unclear. This study aimed to determine the precision of, and agreement and associations between, bone variables assessed via DXA, pQCT, and second-generation HR-pQCT. Thirty older adults (mean age: 64.2 ± 8.0 yr; women: 67%) were recruited. DXA scans were performed at the total hip, lumbar spine, and whole body. Distal (4%) and proximal (30%/33%/66%) skeletal sites at the radius and tibia were scanned with pQCT and/or HR-pQCT. Root-mean-squared coefficients of variation (%CVRMS) were calculated to define precision errors, and Bland-Altman plots assessed agreement between densitometric estimates. Pearson correlations and linear regression explored relationships between bone variables at different skeletal sites and proportional bias, respectively. Precision errors ranged between 0.55% and 1.6% for DXA, 0.40% and 4.8% for pQCT, and 0.13% and 30.7% for HR-pQCT. Systematic bias was identified between pQCT- and HR-pQCT-determined radius and tibia volumetric BMD (vBMD) estimates (all p<.001). Proportional bias was not observed between vBMD measures at any skeletal site (all p>.05). pQCT- and HR-pQCT-determined total, trabecular, and cortical vBMD and estimates of bone strength at the radius and tibia were strongly correlated (all p<.05). Precision error was low for most bone variables and within the expected range for all imaging modalities. We observed significant systematic bias, but no proportional bias, between pQCT- and second-generation HR-pQCT-determined vBMD estimates at the radius and tibia. Nevertheless, measures of bone density and strength were strongly correlated at all skeletal sites. These findings suggest that although bone density and strength estimates from both imaging modalities are not interchangeable, they are strongly related and likely have similar fracture prediction capabilities.
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography