Improved Entropy-Based Condition Monitoring for Pressure Pipeline Through Acoustic Denoising
Yu Wan1, Shaochen Lin1, Chuanling Jin1
1Jiangsu Frontier Electric Technology Co., Ltd., Nanjing 211102, China.
Abstract:
During long-term operation in complex environments, the pressure pipeline systems are prone to damage and faults, and serious safety accidents may occur without real-time condition monitoring. Moreover, in traditional non-contact monitoring approaches, acoustic signals are widely employed for condition monitoring for pressure pipelines, which are easily contaminated by background noise and provide unsatisfactory accuracy. As a tool for quantifying uncertainty and complexity, signal entropy is applied to detect abnormal conditions. Based on the characteristics of entropy and acoustic signals, an improved entropy-based condition monitoring method is proposed for pressure pipelines through acoustic denoising. Specifically, this improved entropy-based noise reduction model is proposed to reduce the noise of monitoring acoustic signals through adversarial training. Based on the denoising of acoustic signals, an abnormal sound detection method is proposed to realize condition monitoring for pressure pipelines. In addition, the experimental platform is built to test the effectiveness and reliability of the proposed method. The results indicate that the quality of signal denoising can reach over 3 dB, while the accuracy of condition monitoring is about 92% for different conditions. Finally, the superiority of the proposed method is verified by comparing it with other methods.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Sound as Pressure Waves
The pressure fluctuation depends on the difference in displacements between the successive points in the...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity...