Related Experiment Video
Updated: May 31, 2025

An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
Iodinated Contrast Adsorption in Cartridges With Styrene-Divinylbenzene Sorbent
Thiago Reis1,2,3, Gonzalo Ramírez-Guerrero3,4, Roberto Pecoits-Filho5,6
1Laboratory of Molecular Pharmacology, Faculty of Health Sciences, University of Brasília, Asa Norte, Brasília, Brazil.
Background:
Contrast-associated acute kidney injury (CA-AKI) is frequent in patients with chronic kidney disease who are submitted to cardiac endovascular procedures using iodinated contrast. In hemoadsorption, cartridges containing styrene-divinylbenzene sorbent resin are applied to remove substances from the blood through an extracorporeal circuit. Importantly, iodinated contrast is also removed via adsorption. We aimed to determine the adsorptive kinetics of the iodinated contrast medium iohexol using a 1:3 scale model of the HA380 cartridge.
Methods:
An experimental in vitro study utilizing a closed-loop extracorporeal circuit with an interposed sorbent cartridge. A solution spiked with iohexol was recirculated for 60 min. Samples for the measurement of iohexol were drawn at 0, 5, 10, 15, 20, 30, 40, and 60 min. The experiment was carried out twice.
Results:
In experiments 1 and 2, the reduction ratio after 60 min was 53.0% and 53.1%, respectively. In experiment 1, iohexol clearance was 46.79 mL/min during the first 5 min and decayed to 3.57 mL/min during the last 20 min. In experiment 2, iohexol clearance was 46.72 mL/min and decayed to 3.87 mL/min during the last 20 min. The ratio of adsorbate/sorbent was 155 mg/g.
Conclusion:
A 1:3 scale model of the HA380 cartridge efficiently removes iodinated contrast in a clinical-scale in vitro circuit. These findings provide a rationale for hemoadsorption as an intervention in clinical trials to prevent or attenuate CA-AKI.
More Related Videos
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
10:14Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Related Concept Videos
Analyte Adsorption and Distribution
Ion-Exchange Chromatography
Ion Exchange
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...