Blood Flow Imaging with Ultrafast Doppler
Published on: October 14, 2020
External delay and dispersion correction of automatically sampled arterial blood with dual flow rates
Benjamin Brender1,2, Lubna Burki3, Josefina Jeon1
1Brain Health Imaging Centre, Centre for Addiction and Mental Health, Toronto, Ontario, Canada.
Abstract:
Objective. Arterial sampling for PET imaging often involves continuously measuring the radiotracer activity concentration in blood using an automatic blood sampling system (ABSS). We proposed and validated an external delay and dispersion correction procedure needed when a change in flow rate occurs during data acquisition. We also measured the external dispersion constant of [11C]CURB, [18F]FDG, [18F]FEPPA, and [18F]SynVesT-1.Approach. External delay and dispersion constants were measured for the flow rates of 350, 300, 180, and 150 ml h-1, using 1-minute-long rectangular inputs (n= 10;18F-fluoride in saline). Resulting constants were used to validate the external delay and dispersion corrections (n= 6;18F-fluoride in saline; flow rate change: 350 to 150 ml h-1and 300 to 180 ml h-1); constants were modelled to transition linearly between flow rates. Corrected curves were assessed using the percent area-under-the-curve (AUC) ratio and a modified model selection criterion (MSC). External delay and dispersion constants were measured for various radiotracers using a blood analog (i.e., similar viscoelastic properties).Main results. ABSS outputs were successfully corrected for external delay and dispersion using our proposed method accounting for a change in flow rate. AUC ratio reduced from ∼10% for the uncorrected 350-150 ml h-1output (∼6% for the 300-180 ml h-1) to < 1% after correction when compared to true input (511 keV energy window); approx. 5-fold increase in MSC. Assuming an internal dispersion constant of 5 s, the dispersion constant (internal + external) for [11C]CURB, [18F]FDG, [18F]FEPPA, and [18F]SynVesT-1 was 13, 9, 16, and 10 s, respectively.Significance. This study presented an external delay and dispersion correction procedure needed when a change in flow rate occurs during ABSS data acquisition. Additionally, this is the first study to measure the external delay and dispersion constants using a blood analog solution, a suitable alternative to blood when estimating external dispersion.
More Related Videos
07:20A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation
Published on: August 30, 2017
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.