Published on: February 6, 2019
Proton minibeam (pMBRT) radiation therapy: experimental validation of Monte Carlo dose calculation in the RayStation
Yuting Lin1, Erik Traneus2, Aoxiang Wang1,3
1Department of Radiation Oncology, University of Kansas Medical Center, KS, United States of America.
Abstract:
Background.Proton minibeam radiation therapy (pMBRT) is a spatially fractionated radiation therapy modality that uses a multi-slit collimator (MSC) to create submillimeter slit openings for spatial dose modulation. The pMBRT dose profile is characterized by highly heterogeneous dose in the plane perpendicular to the beam and rapidly changing depth dose profiles. Dose measurements are typically benchmarked against in-house Monte Carlo (MC) simulation tools. For preclinical and clinical translation, a treatment planning system (TPS) capable of accurately predicting pMBRT doses in tissue and accessible on a commercial platform is essential. This study focuses on the beam modeling and verification of pMBRT using the RayStation TPS, a critical step in advancing its clinical implementation.Methods.The pMBRT system was implemented in RayStation for the IBA Proteus®ONE single-room compact proton machine. The RayStation pMBRT model is an extension of the clinical beam model, allowing pMBRT dose calculations through the MSC using the existing clinical beam model. Adjustable MSC parameters include air gap, slit thickness, slit pitch, number of slits, slits direction and slit thickness. The pMBRT TPS was validated experimentally against measurements using six different collimators with various slit widths (0.4-1.4 mm) and center-to-center slit distances (2.8-4.0 mm). Each collimator comprised five non-divergent slits. Validation involved MatriXX measurements for average dose, Gafchromic film placed at varying depths to measure lateral dose profiles, and film placed along the beam axis to measure depth-dose curves in solid water phantoms. A single 150 MeV energy layer with a 0.5 cm spot spacing was used to create a uniform radiation map across the MSC field.Results.The comparison of average depth dose measurements with RayStation MC calculations showed a gamma passing rate better than 95% using 3 mm/3% criteria, except for the 0.4 mm slit width. After adjusting the slit width by 40-60μm to account for machining uncertainties, the gamma passing rate exceeded 95% under the same criteria. For the peaks and valleys of the percentage depth doses, agreement between RayStation and film measurements was above 90% using 2 mm/5% criteria, except in the high linear energy transfer region. Lateral profile comparisons at depths of 2, 6, and 10 cm demonstrated over 90% agreement for all curves using 0.2 mm/5% criteria.Conclusions.The pMBRT beam model for the Proteus®ONE-based system has been successfully implemented in RayStation TPS, with its initial accuracy validated experimentally. Further measurements, including additional energies and Spread Out Bragg Peaks, are required to complete the clinical commissioning process.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiation: Applications
The average...
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...