Smart oxygen monitoring in hospitals: a pilot study during COVID-19
Jan Velicka1, Martin Pies2, Radovan Hajovsky3
1Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, 70800, Ostrava, Czech Republic. jan.velicka@vsb.cz.
Abstract:
During 2020-2021, the COVID-19 pandemic exposed significant vulnerabilities in hospital safety, with oxygen-related fires and explosions occurring at twice the usual rate. This highlighted insufficient preparedness for increased oxygen therapy demands and the associated risks of oxygen-enriched atmospheres. This study aimed to develop and test a smart monitoring system to detect increased oxygen concentrations in hospital environments, mitigating the risk of fires. Based on Internet of Things (IoT) technology, the system includes wireless sensors that measure oxygen levels at regular intervals and transmit the data to a database. Alerts are sent to hospital staff via short message service and e-mail when oxygen levels exceed predefined thresholds. The sensors were deployed in an intensive care unit and were validated through real-time measurements under hospital conditions. The system demonstrated high accuracy (±1%) in monitoring oxygen concentrations with low power consumption (345 µA for oxygen concentration measurements taken every minute). Notifications reliably informed staff of oxygen level thresholds, enabling timely interventions. The proposed IoT-based smart monitoring system is a cost-effective and efficient solution for improving safety in medical environments.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...


