Related Experiment Video
Updated: May 6, 2026

Coronary Progenitor Cells and Soluble Biomarkers in Cardiovascular Prognosis after Coronary Angioplasty
Published on: January 28, 2020
Assessment of the Severity of Intermediate Coronary Artery Stenosis Using the Systemic Inflammatory Response Index
Serdar Akyel1, Ahmet Korkmaz2, Abdülkadir Yıldız1
1Department of Cardiology, School of Medicine, Kastamonu University, Kastamonu 37150, Turkey.
Abstract:
Background: Fractional Flow Reserve (FFR) is a method that enables the hemodynamic assessment of coronary artery stenosis. The Systemic Inflammatory Response Index (SIRI) is a new marker calculated by multiplying the neutrophil-to-lymphocyte ratio (NLR) with the monocyte count. It is indicative of the presence and severity of coronary artery disease. This study evaluates the relationship between the functional significance of FFR measurements and the SIRI in intermediate coronary stenosis. Methods: A total of 294 patients with 50-70% stenosis in their coronary arteries based on quantitative measurement following angiography who underwent FFR measurement were included in the study before the FFR procedure. Total and differential leukocyte counts and routine biochemical tests were performed. Results: A total of 37% of the patients were found to have a positive FFR, while 63% had a negative FFR. Significant differences were observed in the neutrophil count, monocyte count, Systemic Inflammation Response Index (SIRI), total cholesterol, and amount of adenosine used between the groups (p < 0.05). A SIRI value of 1.16 was 77% sensitive and 55% specific for FFR positivity. Multivariate logistic regression analysis identified the SIRI as an independent predictor of FFR positivity. Conclusions: Our study has demonstrated that high values of the SIRI may serve as a new biomarker for predicting FFR positivity.
More Related Videos
10:28Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Acute Coronary Syndrome III: Diagnostic Studies
Angina III: Clinical Manifestations and Assessment
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease IV: Nursing Management