Rod saturation perimetry. Testing of the cone function with achromatic objects.

V Elenius

    Archives of Ophthalmology (Chicago, Ill. : 1960)
    |April 1, 1985
    PubMed
    Summary

    A woman with cone dysfunction experienced visual field restriction in bright light. Tangential perimetry revealed an absolute ring scotoma, highlighting challenges in diagnosing subtle visual field defects.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Optimizing care for children with difficult-to-treat and severe asthma through specialist paediatric asthma centres: expert practical experience and advice.

    BMC pediatrics·2024
    Same author

    Systemic treatment of children and adolescents with atopic dermatitis aged ≥2 years: a Delphi consensus project mapping expert opinion in Northern Europe.

    Journal of the European Academy of Dermatology and Venereology : JEADV·2022
    Same author

    Field quadrant asymmetry in perimetric thresholds: results of normal and red-green-deficient persons.

    Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde·1994
    Same author

    Perimetric testing of tritan deficiency.

    Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde·1992
    Same author

    Rod thresholds in dominantly inherited juvenile optic atrophy.

    Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde·1991
    Same author

    Visual thresholds measured with red test object on backgrounds of high and low luminance.

    Acta ophthalmologica·1987

    Area of Science:

    • Ophthalmology
    • Visual Neuroscience

    Background:

    • Cone dysfunction is a condition affecting color vision and visual acuity.
    • Standard visual field testing may not detect subtle visual field defects.

    Observation:

    • A patient with slowly progressive cone dysfunction and normal rod function reported visual field restriction in bright light.
    • Normal results were observed with standard Goldmann perimetry.

    Findings:

    • Tangential perimetry using darker test objects on a bright white background revealed a large ring scotoma in both eyes.
    • This ring scotoma became absolute when rod function was saturated using a specific background luminance, indicating severe cone-specific visual field loss.

    Implications:

    • Subtle visual field defects in cone dysfunction may be missed by standard perimetry.
    • Advanced perimetric techniques are crucial for accurate diagnosis and management of retinal disorders.
    • This case underscores the importance of specialized visual field testing for characterizing visual field abnormalities.