Related Experiment Video
Updated: May 31, 2025

Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
A Study on the Impact of Temperature on the Anchoring Durability of Carbon-Fiber-Reinforced Polymer Cables
Minzhe Wang1, Bo Chen2, Haozhe Jiang1
1School of Civil & Environmental Engineering and Geography Science, Ningbo University, Ningbo 315211, China.
Abstract:
To improve the application of carbon-fiber-reinforced polymers (CFRPs) in civil engineering, the long-term durability of CFRP anchorage systems has become a critical issue. Temperature fluctuations can significantly impact the bond performance between CFRPs and the load transfer medium (LTM), making it essential to understand the effects of temperature on the durability of CFRP anchorages. Therefore, this study investigates the influence of temperature on the durability of CFRP anchorages through aging tests on 30 epoxy-filled CFRP-bonded anchorage specimens, followed by pull-out tests. The long-term degradation of CFRP cable anchorage performances in representative regions of the globe was predicted using Arrhenius theory. The experimental results show that after long-term temperature exposure, the maximum bond strength of the CFRP-LTM interface in the anchoring zone degrades after 30 days but continues to increase after 150 days. In contrast, the residual bond strength of the CFRP-LTM interface in the anchorage zone continuously decreases over time, with the degradation rates gradually decreasing over time. Higher temperatures lead to more severe degradation of anchoring performance. Based on the experimental results, it is predicted that the anchoring performance of a CFRP cable anchorage system will reach degradation rates of 63.72%, 83.36%, and 94.73% after 50 years in regions with average annual temperatures of 0 °C, 10 °C, and 20 °C, respectively. Therefore, the temperature has a significant long-term impact on the anchoring performance of CFRP cable bonding systems, necessitating a more conservative design in higher-temperature areas.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
07:48Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Published on: January 29, 2020
Related Concept Videos
Cable Subjected to a Distributed Load
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Cable Subjected to Concentrated Loads
Temperature Dependent Deformation
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Cold Weather Concreting
To counteract the negative impacts of cold weather, ensuring...