Related Experiment Video
Updated: May 31, 2025

Single Cell Measurement of Dopamine Release with Simultaneous Voltage-clamp and Amperometry
Published on: November 21, 2012
Electrochemical Study and Determination of Homovanillic Acid, the Final Metabolite of Dopamine, Using an Unmodified
Mihaela Buleandră1, Lavinia Georgiana Voica1, Dana Elena Popa1
1Department of Analytical Chemistry and Physical Chemistry, Faculty of Chemistry, University of Bucharest, Panduri Avenue 90-92, District 5, 050663 Bucharest, Romania.
Abstract:
This paper summarizes the main findings of a study which aimed to examine the electrochemical oxidation of homovanillic acid (HVA), the final metabolite of dopamine. A pencil graphite electrode (PGE) was used as working electrode and the measurements were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The type and the composition of the graphite leads used as PGE, the pH of the supporting electrolyte, as well as the scan rates were optimized by CV. The analyte was irreversibly oxidized in Britton-Robinson buffer (BRB) solutions. The interpretation of the voltammetric signals and the correlation of the acquired information were the key to addressing the electrode process undergone by HVA at the PGE. The outcomes of the pH and scan rate studies led to the conclusion that two electrons and two protons were involved in the diffusion-controlled process. Using the PGE, a linear relationship between peak current and HVA concentration was obtained between 1.0 × 10-6 M and 5.0 × 10-5 M by DPV in BRB with pH 2.0. The detection limit of 3.84 × 10-7 M was calculated. The accuracy, the precision, and the selectivity of the quantitative method have successfully undergone evaluation. The practical application of the developed voltammetric method was checked by determining the HVA concentration in spiked plasma samples, yielding good recovery values.
More Related Videos
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Cyclic Voltammetry
Interfacial Electrochemical Methods: Overview