Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Evaluation of Conventional and Combined Doppler Parameters in Preeclampsia: Diagnostic and Prognostic Insights
Gulsan Karabay1, Burak Bayraktar1, Zeynep Seyhanli1
1Department of Obstetrics and Gynecology, Division of Perinatology, Ankara Etlik City Hospital, Ankara 06170, Turkey.
Abstract:
Background: The aim of this study was to examine the relationship between conventional and novel Doppler parameters, including cerebroplacental ratio (CPR), cerebral-placental-uterine ratio (CPUR), umbilical-to-cerebral ratio (UCR), and amniotic-to-umbilical-cerebral ratio (AUCR), with the diagnosis of preeclampsia (PE) and adverse neonatal outcomes in PE cases. Methods: This prospective case-control study was conducted at the Ankara Etlik City Hospital Perinatology Clinic between November 2023 and May 2024. The study population was divided into two groups: Group 1, consisting of 74 patients diagnosed with preeclampsia, and Group 2, consisting of 80 healthy control patients. Composite adverse perinatal outcomes (CANOs) include presence of at least one adverse outcome: 5th-minute APGAR score < 7, transient tachypnea of the newborn (TTN), respiratory distress syndrome (RDS), need for continuous positive airway pressure (CPAP), need for mechanical ventilation, neonatal intensive care unit (NICU) admission, neonatal hypoglycemia, need for phototherapy, intraventricular hemorrhage (IVH), and neonatal sepsis. Results: The CPR, CPUR, and AUCR were significantly lower in the PE group compared to the control group, while the UCR was notably higher in the PE group. Among the combined ratios, the CPUR exhibited the highest diagnostic performance for both PE diagnosis and the prediction of CANOs. Additionally, while the UCR, CPR, and AUCR were significant for PE diagnosis, only AUCR demonstrated a significant association with the prediction of CANOs. Conclusions: Combined Doppler parameters, especially CPUR and AUCR, offer valuable insights into diagnosing PE and predicting CANOs. CPUR demonstrated the highest diagnostic accuracy, underscoring its potential utility in clinical settings.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure