Lower Limb Biomechanical Analysis of Healthy Participants
Published on: April 15, 2020
Is the EnodePro® a Valid Tool to Determine the Bar Velocity in the Bench Press and Barbell Back Squat? A Comparative
Nina Behrmann1,2, Martin Hillebrecht2, José Afonso3
1Institute of Sport Science, Carl von Ossietzky University of Oldenburg, 26129 Oldenburg, Germany.
Abstract:
In recent years, the EnodePro® device has been one of the most frequently used velocity sensors to track the bar velocity in resistance training, with the aim of providing load-velocity profiles. However, recent articles highlight a lack of reliability and validity in the estimated maximal strength, which can cause a serious health risk due to the overestimation of the bar velocity. With this study, we aimed to investigate whether imprecision in the measurement could explain the variance in this measurement error.
Methods:
The research question was evaluated by comparing the integrated velocities from the EnodePro® with the velocities from a high-resolution displacement sensor for the squat and bench press. The velocity was measured with loads corresponding to 30%, 50%, and 70% of the one-repetition maximum (1RM) in moderately trained participants (n = 53, f = 16, m = 37). Intraclass correlation coefficients (ICC) for agreement were supplemented by an exploration of the systematic bias and the random error (mean absolute error (MAE), mean absolute percentage error (MAPE)).
Results:
The results indicated movement specificity, with the ICC values for the squat ranging from 0.204 to 0.991 and with ICC = 0.678-0.991 for the bench press. Systematically higher velocities were reported by the EnodePro® sensor (p < 0.001-0.176), with an MAE = 0.036-0.198 m/s, which corresponds to an MAPE of 4.09-42.15%.
Discussion:
The EnodePro® seems to provide overly high velocities, which could result in the previously reported overestimation of the 1RM. Despite the validity problems of force/load-velocity profiles, we suggest evaluating the bar velocity with accurate measurement devices, which is, contrary to previous reports, not the case with the EnodePro®.
More Related Videos
07:30Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
Published on: May 1, 2018
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Related Concept Videos
Non-destructive Tests for Concrete Strength
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...