Related Experiment Video
Updated: May 30, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Multiscale Numerical Study of Enhanced Ductility Ratios and Capacity in Carbon Fiber-Reinforced Polymer Concrete
Moab Maidi1,2, Gili Lifshitz Sherzer3, Erez Gal1
1Department of Civil and Environmental Engineering, Ben-Gurion University of the Negev, Beer Sheva 8410501, Israel.
Abstract:
Rigid reinforced concrete (RC) frames are generally adopted as stiff elements to make the building structures resistant to seismic forces. However, a method has yet to be fully sought to provide earthquake resistance through optimizing beam and column performance in a rigid frame. Due to its high corrosion resistance, the integration of CFRP offers an opportunity to reduce frequent repairs and increase durability. This paper presents the structural response of CFRP beams integrated into rigid frames when subjected to seismic events. Without any design provision for CFRP systems in extreme events, multiscale simulations and parametric analyses were performed to optimize the residual state and global performance. Macroparameters, represented by the ductility ratio and microfactors, have been analyzed using a customized version of the modified compression field theory (MCFT). The main parameters considered were reinforcement under tension and compression, strength of concrete, height-to-width ratio, section cover, and confinement level, all of which are important to understand their influence on seismic performance. The parametric analysis results highlight the increased ductility and higher load-carrying capacity of the CFRP-reinforced tested component compared to the RC component. These results shed light on the possibility of designing CFRP-reinforced concrete components that could improve ductile frames with increased energy dissipation and be suitable for applications in non-corrosive seismic-resistant buildings. This also shows reduced brittleness and enhancement in the failure mode. Numerical simulations and experimental results showed a strong correlation with a deviation of about 8.3%, underlining the reliability of the proposed approach for designing seismic-resistant CFRP-reinforced structures.
Related Concept Videos
Fiber Reinforced Concrete
Design of Prismatic Beams for Bending
Design Example: Distributing Reinforcements in Concrete Sections
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Reinforcements in Concrete
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...

