[Decrease in the electrostimulation threshold of the heart by saturating the electrode with glucocorticoids].

Iu Iu Bredikis, I Iu Skuchas, P P Stirbis

    Biulleten' Eksperimental'Noi Biologii I Meditsiny
    |March 1, 1985
    PubMed
    Summary

    A novel pacing electrode releases glucocorticoids to lower the heart pacing threshold. Animal studies confirm dexamethasone-saturated electrodes significantly reduce pacing energy requirements.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    [The value of digital-analog Holter monitoring systems in the noninvasive diagnosis of heart rhythm disorders].

    Kardiologiia·1993
    Same author

    [Use of an implanted spinal neurostimulator in treatment-resistant stenocardia].

    Kardiologiia·1992
    Same author

    [Ablation of ventricular tachycardia in thoracotomy without artificial circulation].

    Kardiologiia·1991
    Same author

    [Surgical treatment of Wolff-Parkinson-White syndrome: analysis of the methods and results].

    Kardiologiia·1990
    Same author

    [Continuous bipolar electrostimulation of the heart].

    Kardiologiia·1990
    Same author

    [The first clinical experience in extended myoventriculoplasty with programmed cardiosynchronized electroneurostimulation].

    Grudnaia i serdechno-sosudistaia khirurgiia·1990

    Area of Science:

    • Biomedical Engineering
    • Cardiology
    • Materials Science

    Context:

    • Cardiac pacing requires effective electrodes to deliver electrical stimulation.
    • High pacing thresholds necessitate increased energy delivery, potentially leading to discomfort and reduced battery life.
    • Reducing pacing thresholds is crucial for improving patient outcomes and device longevity.

    Purpose:

    • To design and evaluate a novel cardiac pacing electrode.
    • To investigate the efficacy of glucocorticoid elution from a porous electrode surface.
    • To determine if dexamethasone saturation can reduce cardiac pacing thresholds.

    Summary:

    • A porous pacing electrode was developed and saturated with glucocorticoids.
    • Pre-implantation saturation with dexamethasone was performed.

    Related Experiment Videos

  • Animal studies demonstrated a significant reduction in cardiac pacing thresholds using the modified electrode.
  • Impact:

    • This innovation could lead to more efficient cardiac pacing therapies.
    • Reduced pacing thresholds may allow for smaller batteries and less invasive device implantation.
    • Further research may optimize drug-eluting electrodes for various cardiac conditions.