Related Experiment Video
Updated: May 30, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Controlling the energies of the single-rotor large wind turbine system using a new controller
Habib Benbouhenni1, Nicu Bizon2,3, Ilhami Colak4
1Department of Electrical Engineering, LAAS laboratory, National Polytechnic School of Oran- Maurice Audin, Oran El M'naouer, 1523, BP, Algeria. habib.benbouhenni@enp-oran.dz.
Abstract:
In wind energy generation systems, ensuring high energy quality is critical but is often compromised due to the limited performance and durability of conventional regulators. To address this, this work presents a novel controller for managing the machine-side inverter of a single-rotor large wind turbine system using an induction machine-type generator. The proposed controller is designed using proportional, integral, and derivative error-based mechanisms, which fundamentally differ from traditional proportional-integral (PI) regulators. Key features of the proposed regulator include its simplicity, cost-effectiveness, ease of implementation, reduced number of gains, and rapid dynamic response.This regulator enhances the direct power control (DPC) approach, as it integrates two tailored controllers alongside a pulse width modulation strategy to manage the machine inverter. The DPC strategy incorporating the proposed controller was implemented and tested using MATLAB, with various simulations to evaluate its performance and effectiveness. The proposed regulator demonstrated a significant improvement over the PI regulator, with reductions in active power ripples of 69%, 61.70%, and 59.14% across different tests. Additionally, the steady-state error of reactive power was reduced by 54.84%, 85.23%, and 62.68%, and the total harmonic distortion of current decreased by 48.12%, 50.55%, and 56.05%. These results underscore the high efficiency, robustness, and effectiveness of the proposed controller in improving system performance compared to conventional PI regulators. The controller's outstanding performance makes it a promising solution for broader industrial applications.
Related Concept Videos
Turbine-Governor Control
Generator Voltage Control
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
PID Controller
Load-frequency control
Control of Power Flow