Related Experiment Videos
Stress ventricular function test in conscious, nonthoracotomised dogs to assess cardiac drug efficacy
Abstract:
The measurement of left ventricular (LV) function is frequently performed in unconscious or thoracotomised animals in the resting state; these conditions may seriously affect the basal haemodynamic state. To assess myocardial function in conscious animals, a technique was developed to place a catheter across the atrial septum into the left ventricle without a thoracotomy. A stress ventricular function test (SVFT) was performed by raising the systemic blood pressure with methoxamine in the conscious dog. In order to demonstrate the effectiveness of the SVFT in the detection of a decrease in ventricular function, a SVFT was performed before and after the acute infusion of verapamil to determine resting and reserve LV function. A slope relating systolic aortic pressure to the LV end-diastolic pressure was obtained in 10 dogs using a low dose (0.005) and in four dogs a high dose (0.01 microgram X kg-1 X min-1) verapamil (V). The mean slope before V was 3.6 +/- 1.2 and after 2.0 +/- 0.92 (p less than 0.001). The day-to-day variability of the SVFT was less than 22% (coefficient of variability). The SVFT is a sensitive, reproducible method to assess resting and increased or decreased myocardial contractility and is useful in selecting appropriate doses of cardiac drugs to determine their effect on the myocardium during acute and chronic infusion studies in the conscious, nonthoracotomised dog.