Related Experiment Video
Updated: May 2, 2026

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
Published on: December 22, 2015
Calibration of backscattering coefficients with coherent heterodyne lidar utilizing molecular scattering
Abstract:
Coherent heterodyne lidars are typically used for windspeed and attenuated backscattering measurements. The lack of molecular backscattering detection capability has limited the calibrated backscattering measurements until recent advances in coherent lidar technology. In this work, the simultaneous detection of aerosol and molecular backscattering is demonstrated with coherent heterodyne lidar, and the results are compared with a state-of-the-art Raman lidar PollyXT as a reference in a long-range for the first time. The molecular scattering is measured up to 3 km altitude and the extinction of laser power is calculated based on the attenuation. The essential corrections for the molecular scattering data are described and discussed. The backscattering coefficients are calculated with simple high spectral resolution lidar algorithms and the low altitude overlap is calibrated with on-site ceilometer data. A successful high spectral resolution measurement within coherent heterodyne lidar enables the self-calibration of the measured data and removes guessing of the backscatter to extinction ratio and initial values for the typical inversion algorithms. The self-calibration also enables basic aerosol classification based on the measured backscatter to extinction ratios.
More Related Videos
11:34Controlled Synthesis and Fluorescence Tracking of Highly Uniform PolyN-isopropylacrylamide Microgels
Published on: September 8, 2016
09:46Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
Published on: April 28, 2022
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...