Development and application of a non-targeted analysis method using GC-MS and LC-MS for identifying chemical
John T Sloop1,2,3, Jonathan S Casey1,2, Hannah Liberatore4
1Oak Ridge Institute for Science and Education (ORISE) Participant, Research Triangle Park, NC 27711, USA.
Abstract:
While many chemicals are regulated and routinely monitored in drinking water, they represent just a portion of all contaminants that may be present. Typical drinking water analyses involve sampling one liter or less of water, which could lead to trace level contaminants going undetected. In this study, a method was developed for using point-of-use activated carbon block drinking water filters as sampling devices. The filters were extracted to remove chemicals that were collected, and then analyzed by non-targeted analysis via liquid chromatography and gas chromatography high-resolution mass spectrometry. Extraction efficiencies were assessed by spiking and recovery experiments to better understand the chemical space coverage. To test the method's applicability to real-world samples, filters from a small-scale pilot study were collected from individuals in New York, NY and Atlanta, GA and analyzed. Twenty tentatively identified chemical candidates were confirmed by comparison to chemical standards. Principal components analysis was performed on the full set of filtered chemical features to explore how geographic and temporal differences in samples impact drinking water composition. Product use categories for confirmed chemicals were explored to determine potential sources of contaminants.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II