Wavefront aberrations in aging measured with Hartmann-Shack at 3- and 5-mm pupil sizes
Christopher A Clark, Vamsi Parimi1, Ann E Elsner
1School of Optometry, Indiana University, Bloomington, Indiana.
Summary
Using a 3-mm pupil for visual acuity (VA) testing reduces optical aberrations and variability, improving retinal health assessment. This method is less affected by age-related astigmatism changes compared to a 5-mm pupil.
Area of Science:
- Ophthalmology
- Optometry
- Vision Science
Background:
- Visual acuity (VA) measurements can be confounded by optical aberrations, especially in aging eyes.
- These aberrations can lead to inaccurate assessments of retinal health and increased measurement variability.
- A 3-mm pupil approximates the theoretical optical size for optimal VA.
Purpose of the Study:
- To quantify and compare wavefront aberrations for 3-mm and 5-mm pupils.
- To assess the impact of pupil size on VA measurements intended for retinal health evaluation.
- To investigate the influence of age on wavefront aberrations.
Main Methods:
- Wavefront aberrations were measured in 39 normally sighted adults using a 3-mm and 5-mm pupil setting.
- Measurements were taken without pupil dilation using a Pentacam AXL WAV instrument.
- Zernike terms (orders 1-6) were computed, and test-retest variability was analyzed.
Main Results:
- A 3-mm pupil resulted in significantly reduced average wavefront aberrations compared to a 5-mm pupil (21 of 26 Zernike values, p<0.05).
- The 3-mm pupil exhibited significantly less variability in Zernike values across all aberrations (F=54.625, p<0.001).
- Age-related changes in aberrations were noted for vertical astigmatism, horizontal coma, spherical aberration, and vertical quadrafoil, with increased against-the-rule astigmatism in older adults.
Conclusions:
- Utilizing a 3-mm pupil for VA measurements can minimize the influence of anterior segment optical factors on retinal health assessments.
- Reduced wavefront aberrations and variability with a 3-mm pupil enhance the reliability of VA measurements.
- Age-related changes in astigmatism, particularly the increase in against-the-rule astigmatism, should be considered in visual assessments.