Related Experiment Video
Updated: May 30, 2025

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
Video Laryngoscopy for Endotracheal Intubation: A Consideration for Manual In-Line Stabilization Without Cervical
Kasamon Aramvanitch1, Sittichok Leela-Amornsin2, Welawat Tienpratarn1
1Department of Emergency Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.
Introduction:
Traumatic patients with cervical spine motion restriction have difficulty with endotracheal intubation (ETI) due to the limitations of neck movement and mouth opening. Nevertheless, the removal of the cervical collar for ETI in a prehospital setting may lead to a deterioration in neurological outcomes. This study compares the success rate of ETI utilizing a video laryngoscope (VL) on a manikin, contrasting manual in-line stabilization (MILS) without a cervical hard collar against full immobilization.
Methods:
A randomized, non-crossover study was conducted involving 56 paramedic students assigned by SNOSE to utilize various box sizes for VL intubation with MILS without a cervical hard collar or full immobilization technique on a manikin. The primary outcome was the intubation success rate. Secondary outcomes included attempts, time for successful intubation, and Cormack-Lehane classification.
Results:
Fifty-six participants were evaluated; 28 were in the full immobilization group, and another 28 were in the MILS without cervical hard collar group. Baseline characteristics showed no difference between both groups. The success rate of VL intubation showed no difference between the full immobilization group and the MILS without a cervical hard collar group (28 [100%] vs 28 [100%]; 24 [85.71%] vs 27 [96.43%] on first attempt; 4 [14.29%] vs 1 [3.57%] on second attempt; p-value 0.352). Time required to perform successful intubation (median [IQR] 17.20 [12.53, 24.40] vs 17.53 [14.06, 23.73], p-value 0.694) and Cormack-Lehane classification (11 [39.29%] vs 10 [35.71%] in grade I; 16 [57.14%] vs 17 [60.71%] in grade II; 1 [3.57%] vs 1 [3.57%] in grade III, p-value 1.000) showed no statistical difference between the two groups.
Conclusion:
It is unnecessary to remove the cervical hard collar when performing endotracheal intubation while using a video laryngoscope.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...