O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Carbon Dioxide Sensing Based on Off-Axis Integrated Cavity Absorption Spectroscopy Combined with the Informer and
Kehao Zhang1, Tao Wu1, Linlin Shen2
1Key Laboratory of Nondestructive Test (Ministry of Education), Nanchang Hangkong University, Nanchang 330063, China.
Abstract:
Off-axis integrated cavity output spectroscopy (OA-ICOS) allows the laser to be reflected multiple times inside the cavity, increasing the effective absorption path length and thus improving sensitivity. However, OA-ICOS systems are affected by various types of noise, and traditional filtering methods offer low processing efficiency and perform limited feature extraction. Deep learning models enable us to extract important features from large-scale, complex spectral data and analyze them efficiently and accurately. We propose a carbon dioxide (CO2) sensor operating in the near-infrared spectral region (1.602 μm) based on OA-ICOS and deep learning models. A radiofrequency (RF) noise source is employed to reduce the cavity-mode noise in OA-ICOS and thus improve the signal-to-noise ratio (SNR). A time-series-based neural network, known as the informer, is employed for filtering CO2 spectral time series. After filtering, spectral features are directly extracted from the filtered spectral data and CO2 concentrations are predicted using a multilayer perceptron (MLP) model. Our results showed that the SNR attained using informer filtering approximately double those obtained using traditional filtering methods (Savitzky-Golay filtering, Kalman filtering, and wavelet threshold). The linear correlation coefficient (R2) between measured concentrations and standard concentrations was increased from 79.74% (obtained by using the absorption-peak-fitting method) to 98.52% (obtained by using the proposed MLP model). Moreover, the detection limit of the CO2 sensor using the MLP model reached 1.38 ppm at 224.4 s, a 3.79-fold improvement compared to that obtained by using the absorption-peak-fitting method. Our results demonstrate the feasibility of integrating deep learning methods in the field of spectroscopy-based sensing and provide a promising approach for spectral data processing.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Gas Chromatography: Types of Detectors-II
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...