Abstract:
Nasal high flow (NHF) therapy is an established form of non invasive respiratory support used in acute and chronic care. Recently, a new high flow nasal cannula with asymmetric prongs was approved for clinical use. The clinical benefits of the new cannula have not yet been defined and no evidence are available on the use of asymmetric NHF support in patient with Chronic Obstructive Pulmonary Disease (COPD). We conducted a single-centre, prospective, physiologic, crossover, randomised study to investigate the effects on partial pressure of carbon dioxide (PaCO2) levels of two different nasal cannula ("asymmetric" vs "standard" nasal interface) in 20 COPD hypercapnic patients. All patients were recovering from an acute exacerbation that required hospitalisation and had persistent hypercapnia, despite having attained a stable pH. After enrolment, two 90-min trials with the asymmetric nasal high flow interface (Optiflow + Duet, Fisher & Paykel Healthcare Ltd., New Zealand) or the standard interface (Optiflow, Fisher & Paykel Healthcare Ltd., New Zealand) were randomly applied and a washout period of 60 min between the two treatments was performed for minimising the carryover effect. Study results suggested that the asymmetrical cannula did not significantly decrease PaCO2 compared with the standard cannula. Similar performances were also observed in terms of diaphragm activity, dyspnoea and patient's comfort. Interestingly, asymmetric NHF cannula performed significantly better in reducing the dead space ventilation and increasing the ventilatory efficiency in more advanced COPD patients with more severe hypercapnia higher baseline PaCO2 values (PaCO2 ≥ 65 mmHg at baseline). .
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Respiratory Failure-III
Hyperpnea and Hyperventilation
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...