Related Experiment Video
Updated: Jul 6, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Influence of different polymeric materials of implant and attachment on stress distribution in implant-supported
Sherif Elsayed1, Yousra Ahmed2, Mohamed I El-Anwar3
1Al-Ryada University for Science and Technology, Sadat City, Menoufia, Egypt.
Purpose:
Investigating high performance thermoplastic polymers as substitutes to titanium alloy, in fabrication of implants and attachments to support mandibular overdenture, aiming to overcome stress shielding effect of titanium alloy implants. AIM OF STUDY: Assessment of stress distribution in polymeric prosthetic components and bone around polymeric implants, in case of implant-supported mandibular overdenture.
Materials And Methods:
3D finite element model was established for mandibular overdenture, supported bilaterally by two implants at canine region, and retained by two ball attachments. Linear static stress analysis was carried out by ANSYS 2020 R1. Three identical models were created with different materials for modeling of prosthetic components (implant body, gingival former, ball attachment and matrix). The Monolithic principle was applied as the same material was used in modelling all the prosthetic components in each model (Titanium alloy grade V, poly-ether-ether-ketone (PEEK) and poly-ether-ketone-ketone (PEKK)). Simultaneous Force application of 60 N was carried out bilaterally at the first molar occlusal surface area using 3 runs (vertical, lateral and oblique).
Results:
PEEK and PEKK prosthetic components exhibited the highest total deformation and critical Maximum von Mises stresses values in implant body and gingival former under lateral and oblique loads. The stress values approached the fatigue limit of both polymeric materials presenting low factor of safety (< 1.5). The Peri-implant cortical bone in case of PEEK and PEKK showed nearly double maximum principal stresses compared with the titanium model. Conversely, Maximum von Mises stresses in spongy bone were lower in polymeric models than those of titanium ones. Additionally maximum equivalent strain values in spongy peri-implant bone of polymeric models were also lower than those of titanium model.
Conclusion:
Critical high stresses were induced in implant body and gingival former under oblique or lateral loadings, accordingly, fatigue failure of both PEEK and PEKK polymer prosthetic elements was estimated due to low factor of safety. Both PEEK and PEKK Polymer models offered no advantage over titanium one regarding stress shielding effect, due to low stress and strain values generated at spongy peri-implant bone in polymer models.
More Related Videos
07:16Finite Element Analysis Model for Assessing Expansion Patterns from Surgically Assisted Rapid Palatal Expansion
Published on: October 20, 2023
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Plastic Behavior
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Stress Concentrations
Residual Stresses
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each...
Transformation of Plane Stress