Related Experiment Video
Updated: May 7, 2026

17:14
Compact Quantum Dots for Single-molecule Imaging
Published on: October 9, 2012
18.0K
Colloidal Quantum-Dot Heterojunction Imagers for Room-Temperature Thermal Imaging
Ge Mu1, Xiaolong Zheng1, Yimei Tan1,2
1School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China.
Advanced Materials (Deerfield Beach, Fla.)
|January 31, 2025
Summary
Colloidal quantum dots enable room-temperature mid-wave infrared imaging. Band-engineered heterojunctions in mercury telluride quantum dots suppress dark current for sensitive thermal imaging above 250 K.
Area of Science:
- Optoelectronics
- Materials Science
- Quantum Dot Technology
Background:
- Room-temperature operation is crucial for cost-effective mid-wave infrared (MWIR) devices.
- Colloidal quantum dots (CQDs) are promising for next-generation infrared focal plane array (FPA) imagers.
- High-operation temperature (HOT) capabilities reduce system complexity and cost.
Purpose of the Study:
- To demonstrate room-temperature MWIR imaging using CQDs.
- To suppress dark current in mercury telluride (HgTe) CQDs via band-engineered heterojunctions.
- To achieve high-performance thermal imaging with CQD-based FPAs.
Main Methods:
- Fabrication of band-engineered heterojunctions using well-passivated HgTe CQDs.
- Development of single-pixel scanning for MWIR imaging.
- Construction of a 640 × 512 FPA for sensitive thermal imaging.
Main Results:
- Achieved room-temperature MWIR imaging capabilities.
- Demonstrated suppression of dark current in HgTe CQD photodetectors.
- Obtained a room-temperature detectivity of 1.26 × 1010 Jones.
- Reached a noise equivalent temperature difference (NETD) of 25 mK up to 200 K.
Conclusions:
- Band-engineered HgTe CQD heterojunctions enable high-performance room-temperature MWIR imaging.
- The developed technology is suitable for sensitive thermal imaging FPAs operating above 250 K.
- CQDs represent a viable material for advanced infrared optoelectronics.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Total Internal Reflection Fluorescence Microscopy
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
Photoluminescence: Applications
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...