Related Experiment Video
Updated: May 30, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Technical note: Evaluation of a transportable linear ion trap mass spectrometer for seized drug screening operated
Alleigh N Couch1, Christina Chang1, J Tyler Davidson1
1Department of Forensic Science, Sam Houston State University, Huntsville, TX, USA.
Abstract:
Increasing seized drug casework submissions and challenges with rapidly triaging seized drug evidence have led to interest in the potential use of instruments for on-site or mobile laboratory drug screening. However, before this type of instrumentation can be implemented, it is imperative to evaluate the capabilities and limitations under controlled laboratory conditions. This study evaluates the BaySpec Continuity™ transportable linear ion trap (LIT) mass spectrometer coupled to a thermal desorption-atmospheric pressure chemical ionization (TD-APCI) source for seized drug screening while operated under controlled laboratory conditions. The target compounds chosen for this study were selected based on controlled substances and cutting agents commonly observed in seized drug casework, including cocaine, methamphetamine, heroin, fentanyl, caffeine, acetaminophen, pseudoephedrine, phenacetin, phentermine, and levamisole. A library-based alarm system screening method was developed and validated for rapid compound identification in seized drug mixtures. Selectivity, repeatability, and reproducibility were evaluated using five simulated seized drug mixtures with known compositions, and the limit of detection was evaluated for each compound. Blind and authentic destroyed casework samples were analyzed to determine the efficacy of this method when applied to real-world samples and a 100% correct identification rate of the controlled substance present was achieved. Additionally, the ability to differentiate isobaric species using tandem mass spectrometry (MS/MS) analysis was demonstrated for methamphetamine and phentermine. The validated library-based alarm screening method shows promise for rapid seized drug screening under controlled laboratory conditions, which supports potential usage in a mobile laboratory setting.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Mass Analyzers: Common Types
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Spectrometers