Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
First true blood pressure measurement with micropulse detection of arterial opening achieved
Alan Murray1, Dingchang Zheng2, Clive J Griffiths3
1Engineering School & Medical Faculty, Newcastle University, Newcastle upon Tyne, UK. alan.murray@newcastle.ac.uk.
Abstract:
There is a well-accepted need for a new more accurate solution to automatic blood pressure measurement, in spite of clinical convenience continuing to encourage the adoption of oscillometric devices with their known poor accuracy throughout healthcare. Our solution avoids estimates, mathematical modelling, oscillometric algorithms, and inadequate calibration against numerous private clinical data sets. Here we show that our new technique detects, from an arm cuff, micropulses associated with arterial opening between systolic and diastolic pressures; hence detecting systole at the first micropulse and diastole at the last, during cuff deflation. Our technique has equivalent accuracy to the gold standard auscultatory method, and is significantly better than the requirements of the current international standard for blood pressure devices. Our results provide scientific evidence for the effectiveness of our technique, and demonstrate significant clinically important improvements. We anticipate that our technique can be automated easily and economically. We acknowledge that this early study is an initial manual evaluation, but expect this new technique to be an automated universal solution for true blood pressure measurement, and a vital step change in an important clinical measurement in healthcare of the worldwide population.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: