Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Early detection of Bronchopulmonary Dysplasia (BPD) in preterm infants using doppler ultrasound technology
Pin Wang1, Lihong Duan2, Congxin Sun1
1Department of ultrasonography lab, Shijiazhuang No.4 Hospital, Shijiazhuang City 050000, Hebei Province, China.
Objective:
The purpose of this research is to determine if Doppler ultrasonography technology may be used to forecast the onset of bronchopulmonary dysplasia (BPD) in premature babies in the early postnatal stage.
Methods:
On days 3, 7, 14, and 28 after delivery, Doppler ultrasonography exams were performed on a prospective cohort of 170 preterm newborns. Measurements were made of parameters such right ventricular output (RVO), systolic-to-diastolic ratio (S/D ratio), pulmonary artery acceleration time (PAAT), and velocity time integral (VTI). The predictive value of these indicators was evaluated using Kaplan-Meier survival analysis and multivariate logistic regression.
Results:
The severity of BPD was substantially correlated with all assessed Doppler ultrasound parameters (P < 0.05). With an area under the curve (AUC) of 0.76, PAAT in particular demonstrated a reasonable capacity for prediction. A considerably greater cumulative incidence was found by Kaplan-Meier survival analysis.
Conclusion:
In conclusion, Doppler ultrasonography technology is a useful technique for identifying BPD in premature babies early on. High-risk babies can be efficiently identified by PAAT and VTI in particular, allowing for prompt intervention and possibly better results.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...