Related Experiment Video
Updated: Jul 8, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Cardioverter-Defibrillator Implantation as a Risk Factor For Motor Vehicle Crash
John A Staples1, Daniel Daly-Grafstein2, Isaac Robinson3
1Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada; Centre for Clinical Epidemiology and Evaluation, Vancouver, British Columbia, Canada.
Background:
Limited empirical evidence informs fitness-to-drive recommendations after implantable cardioverter-defibrillator (ICD) implantation. Cohort designs can be deceptive because ICD recipients differ from control individuals and may temporarily cease driving after implantation.
Objectives:
This study sought to generate evidence to inform medical driving restrictions after ICD implantation.
Methods:
We used population-based data to identify all drivers involved in a serious motor vehicle crash in British Columbia, Canada, from 1997 to 2019. Exposure was defined as ICD implantation in the 6 months before a crash. One analysis used a case-crossover design to control for relatively fixed individual characteristics like driving experience. Another analysis used a responsibility design to account for road exposure (miles of driving per week). Both analyses used logistic regression with adjustment for potential confounders.
Results:
In the case-crossover analysis of crash-involved ICD recipients, ICD implantation occurred in 212 of 3,299 precrash intervals and in 485 of 6,598 control intervals, suggesting no temporal association between ICD implantation and subsequent crash (6.4% vs 7.4%; adjusted OR [aOR]: 0.86; 95% CI: 0.71-1.03; P = 0.11). In the analysis of all crash-involved drivers with determinate crash responsibility, 14 of 22 drivers with recent ICD implantation and 532,741 of 1,035,433 drivers without recent ICD implantation were deemed responsible for their crash, suggesting no association between ICD implantation and crash responsibility (crude proportion responsible, 64% vs 51%; aOR: 2.20; 95% CI: 0.94-5.30; P = 0.08).
Conclusions:
The 6-month interval after ICD implantation is not associated with increased odds of crash nor with increased likelihood of crash responsibility. Contemporary driving restrictions in the first weeks after ICD implantation appear to adequately mitigate the potential increase in crash risk.
Related Concept Videos
Ischemic Heart Disease: Overview
Atherosclerosis, the primary malefactor, orchestrates this dangerous condition. It manifests as the accumulation of fatty deposits, akin to insidious plaques, within arterial walls. As time elapses, these plaques metamorphose, hardening and narrowing...
Coronary Artery Disease I: Introduction
Coronary Artery Disease IV: Preventive Measures
Cardiopulmonary Resuscitation III: AED Use
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy V: Interprofessional Care