Related Experiment Video
Updated: May 29, 2025

Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Congenital Heart Disease Fetuses Have Decreased Mid-Gestational Placental Flow, Placental Malperfusion Defects,
Rebecca Josowitz1, Deborah Y Ho2, Somya Shankar1
1Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA.
Background:
Placental health may impact the development and outcomes of congenital heart disease (CHD). CHD fetuses have been shown retrospectively to have decreased placental blood flow.
Objectives:
The purpose of this study was to determine if CHD fetuses with decreased placental blood flow have placental pathology at birth and if there is a relationship between placental blood flow, placental pathology, and outcomes.
Methods:
We performed a prospective case-control study of 38 CHD fetuses, including 28 with single ventricle physiology and 36 controls. Demographic, clinical, and postnatal biometric data were collected. Umbilical venous volume flow (UVVF) was measured from 2nd trimester fetal echocardiograms. Placentas underwent standardized pathological analysis. Standard descriptive statistics and regression analyses were performed to analyze the relationship between UVVF, placental defects, and outcomes.
Results:
CHD fetuses had a 15% decrease in mid-gestational UVVF indexed to fetal weight (P < 0.01), and a 27% reduction in UVVF as a proportion of fetal cardiac output (P < 0.01) compared to controls. CHD fetuses had increased placental maternal vascular malperfusion (MVM) lesions (44% vs 18%, P < 0.05), especially high-grade MVM (39% vs 9.1%, P = 0.05), and a trend toward increased placental fetal vascular malperfusion lesions (42% vs 23%, P = 0.10). Placental MVM but not fetal vascular malperfusion lesions were associated with decreased birth weight in CHD fetuses (P < 0.001). There was no association between UVVF and placental pathologic findings or fetal growth.
Conclusions:
CHD (particularly single ventricle) fetuses have decreased mid-gestational placental blood flow, increased placental malperfusion defects, and impaired fetal growth. Placental MVM may influence impaired fetal growth in CHD.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Teratogenicity
Development of Blood Vessels
The initial formation of this system is facilitated by the small amount of yolk present in the ovum and yolk sac. Blood vessels originate from...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...

