Enhancing U-Net-based Pseudo-CT generation from MRI using CT-guided bone segmentation for radiation treatment
Ama Katseena Yawson1,2,3, Habiba Sallem2,3,4, Katharina Seidensaal2,4
1German Cancer Research Center (DKFZ), Division of Medical Physics in Radiation Oncology, Heidelberg, Germany.
Abstract:
Objective.This study investigates the effects of various training protocols on enhancing the precision of MRI-only Pseudo-CT generation for radiation treatment planning and adaptation in head & neck cancer patients. It specifically tackles the challenge of differentiating bone from air, a limitation that frequently results in substantial deviations in the representation of bony structures on Pseudo-CT images.Approach.The study included 25 patients, utilizing pre-treatment MRI-CT image pairs. Five cases were randomly selected for testing, with the remaining 20 used for model training and validation. A 3D U-Net deep learning model was employed, trained on patches of size 643with an overlap of 323. MRI scans were acquired using the Dixon gradient echo (GRE) technique, and various contrasts were explored to improve Pseudo-CT accuracy, including in-phase, water-only, and combined water-only and fat-only images. Additionally, bone extraction from the fat-only image was integrated as an additional channel to better capture bone structures on Pseudo-CTs. The evaluation involved both image quality and dosimetric metrics.Main results.The generated Pseudo-CTs were compared with their corresponding registered target CTs. The mean absolute error (MAE) and peak signal-to-noise ratio (PSNR) for the base model using combined water-only and fat-only images were 19.20 ± 5.30 HU and 57.24 ± 1.44 dB, respectively. Following the integration of an additional channel using a CT-guided bone segmentation, the model's performance improved, achieving MAE and PSNR of 18.32 ± 5.51 HU and 57.82 ± 1.31 dB, respectively. The measured results are statistically significant, with ap-value<0.05. The dosimetric assessment confirmed that radiation treatment planning on Pseudo-CT achieved accuracy comparable to conventional CT.Significance.This study demonstrates improved accuracy in bone representation on Pseudo-CTs achieved through a combination of water-only, fat-only and extracted bone images; thus, enhancing feasibility of MRI-based simulation for radiation treatment planning.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
04:48Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...