Related Experiment Video
Updated: Jul 28, 2026

Localization and Relative Quantification of Carbon Nanotubes in Cells with Multispectral Imaging Flow Cytometry
Published on: December 12, 2013
Ultrasensitive and Selective Nitrogen-Doped Fluorescent Carbon Dots Probe for Quantification Analysis of Trace Cu2+
Zhenning Lou1, Xinyu Zhou2, Xiaomai Hao2
1College of Chemistry, Liaoning University, Shenyang, 110036, PR China. louzhenning@lnu.edu.cn.
Abstract:
As a typical non-ferrous metal, copper is heavily used in the manufacturing and chemical industries. Copper pollution has been demonstrated to have a significant detrimental impact on the natural environment, as well as causing irreparable damage to the human body, such as elevated Cu2+ levels have been identified as a factor in the pathogenesis of AD (Alzheimer's disease). In this study, novel nanoscale carbon dots Blue-CDs (B-CDs) were obtained by the solvothermal approach in formamide solution utilizing citric acid as the carbon source and ethylenediamine as the nitrogen dopant. The particle size of B-CD was assessed to be 2.17 nm, with a quantum yield (QY) of 10.28%. The B-CDs were found to be extinguished upon exposure to Cu2+, which exhibited a good fluorescence detection linear relationship within the concentration range of 0.25-10.0 µM Cu2+, showing a limit of detection (LOD) is 0.18 µM. B-CDs have been effectively used for the measurement of Cu2+ in actual aqueous systems. It is due to the chemical reactions that take place among the B-CDs and the Cu²⁺ that make the sensor highly sensitivities and highly selectivities. The results of the experiment demonstrate that the fluorescence quenching process is a consequence of Cu2+ binding to the amino groups of carbon dots, forming complexes via a non-radiative photoinduced electron transfer process. In conclusion, the described simple sensing techniques could be effectively utilized as monitoring tools for Cu2+ in environmental waters.
Related Concept Videos
UV–Vis Spectrometers
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Precipitation and Co-precipitation
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors