Related Experiment Video
Updated: May 29, 2025

Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Carbon and hydrogen isotope analysis of triacetone triperoxide using solid-phase microextraction coupled to GC-IRMS
Abstract:
The source inference of triacetone triperoxide (TATP) is of great significance in the fight against crime. Isotope ratio mass spectrometry (IRMS) is a reliable method for accurately measuring the isotope ratio, and it has been successfully used to differentiate and trace various explosives, including TATP. However, the current studies are not suitable for analyzing trace amounts of TATP in complex matrices. The matrix at the explosion site is complex, with severe interference and low levels of explosive residues, which makes it difficult to extract the explosive residues. Therefore, an effective method for extracting and enriching TATP is necessary before conducting IRMS analysis. Solid-phase microextraction (SPME) is an efficient extraction technology that combines extraction, concentration and sample injection. In this study, SPME-gas chromatography-isotope ratio mass spectrometry (GC-IRMS) method based on isoreticular metal-organic framework-8 (IRMOF-8) coated fiber was established for the first time for the analysis of δ13C and δ2H signatures of TATP. The limits of detection of δ13C and δ2H signatures of TATP were 100 ng and 9 µg, respectively, with measurement errors of 0.36 ‰ and -3.75 ‰. The IRMOF-8-coated fiber exhibited better mechanical stability and a lower limit of detection compared to the commercial polydimethylsiloxane (PDMS) fiber. Using the established method, six TATP samples from different sources were distinguished accurately. The impact of matrix (soil and tap water) on δ13C and δ2H signatures of TATP was also investigated. The established method demonstrated high sensitivity and precision, making it suitable for in-situ extraction and source of trace explosive residues in explosion cases.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Ion-Exchange Chromatography
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...

