Related Experiment Video
Updated: May 29, 2025

Subcutaneous Neurotrophin 4 Infusion Using Osmotic Pumps or Direct Muscular Injection Enhances Aging Rat Laryngeal Muscles
Published on: June 13, 2017
The Effect of Laryngeal Dehydration and Nebulized Osmotic Agents on the Voice
Tuğba Kaya1, Göksu Yılmaz2, Richard I Zraick3
1Speech and Language Department, University of Health Sciences, İstanbul, Türkiye.
Objective:
This study investigates the effects of dehydration induced by dry air breathing and the nebulization of various osmotic agents on vocal parameters, including perceptual, acoustic, and electroglottographic measures.
Methods:
Thirty normophonic females (age x̅ = 26, SD = 1.67) participated over three consecutive days. On the first day, the baseline data were meticulously collected before the participants underwent a 22-minute session of transoral dry air breathing. Immediately after this desiccation protocol, measurements were taken to establish the initial effects. Subsequently, one of three osmotic agents was randomly selected for each participant. These agents included hypotonic distilled water, 0.9% isotonic saline, and 3% hypertonic saline. Each participant then underwent a 10-minute nebulization session with 5 mL of the assigned osmotic agent. The process was repeated on the second and third days. Each day, the participants again experienced the 22-minute transoral dry air breathing session. The evaluations were performed by Borg CR-10 (perceived vocal effort), electroglottography (EGG), voice onset time (VOT), nasalance score (NS), and cepstral peak prominence analyses with CAPE-V sentences (s).
Results:
No statistically significant differences were found in the EGG parameters between the preliminary recordings, post transoral medical-grade dry air protocol, and after each of task-hypotonic, task-isotonic, and task-hypertonic. Following the transoral medical-grade dry air protocol, both /s1/-CPP and /s5/-CPP values decreased compared with the preliminary recordings. Only /s1/-CPP values increased after the 0.9% isotonic saline nebulization. NS from preliminary measurements was higher for both oronasal and nasal texts compared with scores after the dry air protocol and nebulization. Voiceless plosive VOT values decreased solely after the 0.9% isotonic saline nebulization. Participants' Borg CR-10 scores increased after transoral medical-grade dry air protocol and decreased after nebulization with distilled water and 0.9% isotonic saline.
Conclusions:
Isotonic saline and distilled water nebulization protocols demonstrated a trend toward mitigating the adverse effects of the transoral medical-grade dry air inhalation protocol on vocal parameters.
More Related Videos
07:22Minimally Invasive Murine Laryngoscopy for Close-Up Imaging of Laryngeal Motion During Breathing and Swallowing
Published on: December 1, 2023
05:43Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
Related Concept Videos
Larynx
Anatomy of the Larynx
The larynx consists of various components, including cartilage, muscles, and vocal cords. Its structure includes three large unpaired cartilages—the thyroid, cricoid, and epiglottis—and three smaller paired cartilages—the arytenoids,...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Upper Respiratory Drugs: Antitussives, Expectorants, and Mucolytics
Antitussives include codeine, dextromethorphan (Robitussin), and benzonatate (Tessalon). Codeine and dextromethorphan exert their effects centrally by suppressing the cough reflex center in the medulla. Benzonatate operates peripherally within the respiratory tract by...