Nuclear Magnetic Resonance Spectroscopy for the Identification of Multiple Phosphorylations of Intrinsically Disordered Proteins
Published on: December 27, 2016
Detection of Exchangeable Protons in NMR Metabolomic Analysis Using AI-Designed Water Irradiation Devoid Pulses
Manu Veliparambil Subrahmanian1, Ivan Vuckovic2, Slobodan Macura3
1Department of Biochemistry, Molecular Biology and Biophysics, University of Minnesota, Minneapolis, Minnesota 55455, United States.
Abstract:
1H NMR spectroscopy has enabled the quantitative profiling of metabolites in various biofluids, emerging as a possible diagnostic tool for metabolic disorders and other diseases. To boost the signal-to-noise ratio and detect proton resonances near the water signal, current 1H NMR experiments require solvent suppression schemes (e.g., presaturation, jump-and-return, WATERGATE, excitation sculpting, etc.). Unfortunately, these techniques affect the quantitative assessment of analytes containing exchangeable protons. To address this issue, we introduce two new one-dimensional (1D) 1H NMR techniques that eliminate the water signal, preserving the intensities of exchangeable protons. Using GENETICS-AI, a software that combines an evolutionary algorithm and artificial intelligence, we tailored new water irradiation devoid (WADE) pulses and optimized the 1D 1H NOESY sequence for metabolomic analysis. When applied to human urine samples, kidney tissue extract, and plasma, the WADE technique allowed for accurate measurement of typical metabolites and direct quantification of urea, which is usually challenging to measure using standard NMR experiments. We anticipate that these new NMR techniques will significantly improve the accuracy and reliability of metabolite quantitative assessment for a wide range of biological fluids.
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...
¹H NMR of Labile Protons: Deuterium (²H) Substitution
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)