Related Experiment Video
Updated: May 29, 2025

Snap Chip for Cross-reactivity-free and Spotter-free Multiplexed Sandwich Immunoassays
Published on: November 13, 2017
Rapid, Sensitive Detection of Protein Biomarkers in Minimally-Processed Blood Products with a Monolithic Sandwich
Nicolò Maganzini1, Agnes Reschke2, Alyssa P Cartwright1
1Department of Electrical Engineering, Stanford University, Stanford, CA, 94305, USA.
For more than fifty years, the enzyme-linked immunosorbent assay (ELISA) serves as the gold standard for protein biomarker detection. However, conventional ELISA requires considerable sample preparation including reagent addition, incubation, and washing steps, limiting its usefulness at the point-of-care. In this work, the "instant ELISA" (fluorophore-linked immunosorbent assay) biosensor that can measure protein biomarkers in the picomolar range within 15 min in undiluted plasma or serum with no sample preparation is described. The sensor leverages a synthetic reagent termed the "monolithic dual-antibody clamp" (MDAC) which preserves the specificity, sensitivity, and generalizability of an ELISA, but produces a fluorescence signal as two surface-tethered antibodies form a "sandwich" by binding to two distinct epitopes on the target. As exemplars, picomolar quantification of tumor necrosis factor alpha (TNFα) and monocyte chemotactic protein (MCP)-1, the latter of which is a useful prognostic indicator of cytokine release syndrome in patient plasma samples during chimeric antigen receptor T cell therapy are demonstrated.
For more than fifty years, the enzyme-linked immunosorbent assay (ELISA) serves as the gold standard for protein biomarker detection. However, conventional ELISA requires considerable sample preparation including reagent addition, incubation, and washing steps, limiting its usefulness at the point-of-care. In this work, the "instant ELISA" (fluorophore-linked immunosorbent assay) biosensor that can measure protein biomarkers in the picomolar range within 15 min in undiluted plasma or serum with no sample preparation is described. The sensor leverages a synthetic reagent termed the "monolithic dual-antibody clamp" (MDAC) which preserves the specificity, sensitivity, and generalizability of an ELISA, but produces a fluorescence signal as two surface-tethered antibodies form a "sandwich" by binding to two distinct epitopes on the target. As exemplars, picomolar quantification of tumor necrosis factor alpha (TNFα) and monocyte chemotactic protein (MCP)-1, the latter of which is a useful prognostic indicator of cytokine release syndrome in patient plasma samples during chimeric antigen receptor T cell therapy are demonstrated.
More Related Videos
08:58Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood
Published on: April 16, 2016
10:10Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021