Related Experiment Video
Updated: May 29, 2025

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Construction of Nonenzymatic Flexible Electrochemical Sensor for Glucose Using Bimetallic Copper Ferrite/Sulfur-Doped
Selen Uruc1,2, Ozge Gorduk1, Yucel Sahin1
1Department of Chemistry, Faculty of Arts and Science, Yildiz Technical University, TR34220 Istanbul, Türkiye.
Abstract:
Diabetes is a chronic disease that results in elevated blood glucose levels due to insufficient insulin production by the pancreas or impaired insulin utilization by the body. The development of effective tools for the in vitro detection of blood glucose is of paramount importance. Flexible electrodes serve as indispensable components in point-of-care systems, thus increasing accessibility and personalization in health monitoring. We present the preparation of handmade screen-printed electrode with water-based conductive ink for in vitro nonenzymatic glucose (Glu) determination at physiological pH values. The investigation aimed to identify the optimal conditions for formulating and composing the conductive ink used to create a copper ferrite/sulfur-doped graphene oxide/graphite/screen-printed electrode (CuFe2O4/S-GO/G/SPE). The resulting CuFe2O4/S-GO/G/SPE shows excellent glucose sensing ability with a limit of detection (LOD) of 2.93 μM. The superior determination at physiological pH is attributed to the complex structure formed by CuFe2O4 nanoparticles with glucose molecules in the basic pH conductive ink structure. Additionally, the excellent delocalization and conductivity of the S-GO particles in this complex structure contribute to improved performance. The study on artificial sweat samples resulted in achieving recovery values of 96.60% to 104.97%. In conclusion, the nonenzymatic and noninvasive Glu sensor printed with conductive ink containing CuFe2O4/S-GO/G on a flexible paper substrate surface demonstrated remarkable capabilities for determining Glu levels in artificial sweat samples. SPEs prepared with conductive ink produced by using these materials are promising candidates for use as electrodes in flexible and wearable sensor technology.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
Related Concept Videos
Amperometry: Overview
Potentiometry: Membrane Electrodes