Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
Blood pressure in human large cerebral arteries: a feasibility study
Leena N Shoemaker1,2, Tyson Matern3, Farah Kamar1
1Department of Medical Biophysics, Western University, London, Ontario, Canada.
None:
The lack of direct measures of brain blood pressure (BBP) has severely restricted understanding of cerebral pressure-flow relationships and their control. We sought to evaluate the feasibility of directly measuring BBP and its pulsatility between the aorta and middle cerebral artery (MCA) during elective endovascular surgical procedures. We report five case studies (four female, 61 ± 13 yr; means ± SD) of patients undergoing cerebrovascular interventional procedures for aneurysm and stenoses, using direct BBP measures with the COMET 2 pressure guidewire system (Boston Scientific). Patients were supine, intubated, and under anesthesia. The sensor wire was inserted via the femoral artery, measuring, as feasible, blood pressure (BP) in the aorta to MCA vascular segments, referenced to the radial artery BP waveform (arterial catheter). Mean arterial pressure varied between the radial (80 ± 18 mmHg), internal carotid artery (ICA; 70 ± 25 mmHg), and MCA (62 ± 29 mmHg), and marked interindividual heterogeneity was observed. Pulse pressure was higher in the radial artery (68 ± 23 mmHg) compared with the intracranial ICA (ICAi; 43 ± 29 mmHg) and MCA (M1; 25 ± 12 mmHg) segments. Direct measures of BBP in humans are feasible in this interventional surgery model. Although limited by the small sample size, the results suggest a heterogenous pattern of change between systemic and brain measures of blood pressure and pulse pressure.NEW & NOTEWORTHY We explored the feasibility of making direct measures of blood pressure in the large arteries at the base of the brain in humans. Measures were made with an optical sensor positioned in the aorta, common carotid, internal carotid artery external to the cranium, internal carotid artery within the cranium, and/or middle cerebral artery (MCA), M1 segment. Measures varied across individuals, as did the pressure gradient from systemic pressures to those in the MCA.
More Related Videos
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)