Related Experiment Video
Updated: May 29, 2025

Functional and Physiological Methods of Evaluating Median Nerve Regeneration in the Rat
Published on: April 18, 2020
Description of an alternative method for the electrodiagnostic evaluation of the sensory radial nerve
Martin Moussy1, Julie Rode1, Thierry Maisonobe2
1Hôpital Neurologique Pierre Wertheimer, Service d'ENMG et de Pathologies neuromusculaires, centre de référence des maladies neuromusculaires PACA-Réunion-Rhône Alpes, Hospices Civils de Lyon, Groupement Est, 59 Boulevard Pinel, Bron, France.
Objectives:
The aim of this study was to describe an alternative method for the electrodiagnostic (EDX) evaluation of the sensory radial nerve (SRN).
Methods:
In this retrospective study, all patients from a French EDX center (November 2022-April 2023) for whom SNAP amplitudes of the same SRN were obtained through both a conventional and an alternative method were included. In the conventional method, the active recording electrode was placed at the base of the snuff box, whereas in the alternative method, it was placed 3-4 cm proximally on the lateral border of the radial bone. The SNAP amplitudes of both methods were compared and the ratio of alternative to conventional amplitude was determined within the same patient. A secondary objective was to compare SNAP amplitudes and ratios between patients with peripheral neuropathy and those without (control group).
Results:
Among the 117 patients included, the mean ± SD SNAP amplitude was 50.0±28.9 µV in the alternative method compared to 31.0±17.9 µV in the conventional method. The ratio of alternative to conventional amplitudes was 1.64±0.4 in all patients. No significant difference in amplitude ratios was found between the peripheral neuropathy group (1.63 ± 0.4) and the control group (1.65 ± 0.3; p =0.75).
Discussion:
The alternative method, based on a more proximal placement of the recording electrodes, consistently provided larger SNAP amplitudes than the conventional method. This method could be useful in particular clinical settings but could prove more challenging in obese or muscular patients.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation