Related Experiment Video
Updated: May 29, 2025

Uncoupling Coriolis Force and Rotating Buoyancy Effects on Full-Field Heat Transfer Properties of a Rotating Channel
Published on: October 5, 2018
Data analysis for performance index of plate heat exchanger filled by ionanofluid-oil: parallel versus counterflow
Ishrat Zahan1, Rehena Nasrin2, Nusrat Jahan Jakia1
1Department of Mathematics, Bangladesh University of Engineering and Technology, Dhaka, 1000, Bangladesh.
Abstract:
Plate heat exchangers ensure their continued relevance and adaptability in meeting modern energy, environmental, and industrial demands. Innovations in this area significantly improve energy efficiency, reduce environmental impact, and enhance industrial processes. However, the ionanofluid significantly enhanced the thermal conductivity and heat transfer coefficient compared to conventional fluids. This study focuses on a three-chambered parallel plate heat exchanger (PHE) using cold ionanofluid (a mixture of graphene as nanoparticle and 1-ethyl-3-methylimidazolium thiocyanate ([C2mim][SCN]) as ionic liquid) in the top and bottom channels and hot oil in the middle channel. It aims to determine the most effective configuration for performance index (η) and energy efficiency, given the unique properties of ionanofluid. The governing equations of Navier-Stokes and energy balance are solved numerically using the finite element method. The impact of different Reynolds numbers (Re) and solid concentrations (ϕ) of nanoparticles on the fluid velocity and temperature fields is observed, and various related parameters are calculated. A comprehensive data analysis is conducted using the surface response method, including ANOVA, sensitivity analysis, and optimization testing. The counter and parallel flow designs achieve approximately 76.23% and 70.07% thermal enhancement at Re = 1, respectively. The optimal performance index occurs at (Re = 1, ϕ = 0.025), chosen to maximize predicted η (= 33972.3) and actual η (= 34020.03). The results indicate that the counterflow configuration consistently outperforms the parallel flow configuration regarding heat transfer efficiency. The counterflow configuration exhibited superior overall performance and provided a more uniform temperature distribution across the PHE. This research offers important insights into the application of ionanofluids in heat exchangers by comparing both parallel and counterflow setups. The study demonstrates high R2 values for the response function, highlighting its significance, and suggests practical implications for the optimization of heat exchanger designs in industrial settings.
Related Concept Videos
Steady, Laminar Flow Between Parallel Plates
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Design Example: Flow of Oil Through Circular Pipes
Couette Flow
Fluid Pressure over Flat Plate of Constant Width
The resultant force...