Related Experiment Video
Updated: Apr 28, 2026

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
DLPVI: Deep learning framework integrating projection, view-by-view backprojection, and image domains for high- and
Xuzhi Zhao1, Yi Du2, Yahui Peng1
1School of Electronic and Information Engineering, Beijing Jiaotong University, Beijing, China.
Abstract:
This study proposes a deep learning framework, DLPVI, which integrates projection, view-by-view backprojection (VVBP), and image domains to improve the quality of high-sparse-view and ultra-sparse-view cone-beam computed tomography (CBCT) images. The DLPVI comprises a projection domain sub-framework, a VVBP domain sub-framework, and a Transformer-based image domain model. First, full-view projections were restored from sparse-view projections via the projection domain sub-framework, then filtered and view-by-view backprojected to generate VVBP raw data. Next, the VVBP raw data was processed by the VVBP domain sub-framework to suppress residual noise and artifacts, and produce CBCT axial images. Finally, the axial images were further refined using the image domain model. The DLPVI was trained, validated, and tested on CBCT data from 163, 30, and 30 real patients respectively. Quantitative metrics including root-mean-square error (RMSE), peak signal-to-noise ratio (PSNR), structural similarity (SSIM), and feature similarity (FSIM) were calculated to evaluate the method performance. The DLPVI was compared with 15 state-of-the-art (SOTA) methods, including 2 projection domain models, 10 image domain models, and 3 projection-image dual-domain frameworks, on 1/8 high-sparse-view and 1/16 ultra-sparse-view reconstruction tasks. Statistical analysis was conducted using the Kruskal-Wallis test, followed by the post-hoc Dunn's test. Experimental results demonstrated that the DLPVI outperformed all 15 SOTA methods for both tasks, with statistically significant improvements (p < 0.05 in Kruskal-Wallis test and p < 0.05/15 in Dunn's test). The proposed DLPVI effectively improves the quality of high- and ultra-sparse-view CBCT images.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography

