The difference in arterial baroreflex sensitivity between the supine and standing positions in healthy subjects
Teruhiko Sakamoto1, Satoshi Mitsuyama1, Toru Nagasawa1
1Department of Healthcare Informatics, Takasaki University of Health and Welfare, 37-1 Nakaohrui, Takasaki, Gunma 370-0033, Japan.
Abstract:
The spectral analysis of heart rate variability (HRV) has long been considered a practical, noninvasive tool to assess autonomic nervous functions that regulate the cardiovascular system. The conventional method, however, has limitations in characterizing transient changes of HRV. We have overcome this problem by adopting the time-frequency analysis method. Using this method, we attempted to clarify differences in the arterial baroreflex (ABR) activity during a transient change in the heart rate between the supine and standing positions in healthy subjects. We found that the ABR gain was significantly greater in the supine position compared to standing, and this gain increase was due to transient increases in 0.15 to 0.20 Hz components of HRV spectral powers caused by enhanced cardiac vagal outflow. Based on these findings, we conclude that the orthostatic stress induced by the postural change from supine to standing markedly reduces the baroreflex gain by suppressing high-frequency cardiac vagal outflow.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure