Related Experiment Video
Updated: May 28, 2025

Microwave-assisted Intramolecular Dehydrogenative Diels-Alder Reactions for the Synthesis of Functionalized Naphthalenes/Solvatochromic Dyes
Published on: April 1, 2013
Fluorescence Emission and Absorption Spectra of Naphthalene in Cyclohexane Solution: Evidence of a Naphthalene-Oxygen
J Thomas Brownrigg1, Jonathan E Kenny1
1Department of Chemistry, Tufts University, 62 Talbot Avenue, Medford, Massachusetts 02155, United States.
Abstract:
Molecular fluorescence is typically reduced or "quenched" by dissolved oxygen present in solutions. Quenching mechanisms are broadly categorized as dynamic quenching, and static quenching. Dynamic quenching involves collisions between oxygen and the fluorophore. Static quenching occurs when the fluorophore forms a nonfluorescent complex with oxygen. In a previous study, oxygen quenching of naphthalene showed evidence of static quenching, although the mechanism was not known. The earlier work was limited to low oxygen concentrations (∼2 mM) in cyclohexane, leading to relatively large uncertainties in the value of the static quenching constant. In the present study, oxygen concentrations up to ∼50 mM were used, resulting in a more accurate determination of the static quenching constant. Absorption spectra obtained at higher oxygen concentrations revealed the spectrum of a new species, which we interpret as that of a naphthalene-oxygen charge-transfer complex. The binding energy of the naphthalene-oxygen complex was estimated and compared with that of the benzene-oxygen complex. In the method described herein, the equilibrium (or association) constant for the naphthalene-oxygen complex was assumed to be the static quenching constant, as determined from graphs of relative fluorescence intensities vs oxygen concentration using the Stern-Volmer formalism. The values of the complex molecular absorption coefficients were determined from graphs of absorbance vs oxygen concentration using the value of the static quenching constant from fluorescence data. This method differs from a commonly used method in which graphs of absorbance vs oxygen concentration are used to determine the product of the equilibrium constant and the complex absorption coefficient. The latter method can lead to substantial errors in both these quantities if the spectrum of the free molecule and complex overlap significantly.
More Related Videos
Related Concept Videos
Variables Affecting Phosphorescence and Fluorescence
UV–Vis Spectroscopy: Molecular Electronic Transitions
Aromatic Hydrocarbon Cations: Structural Overview
Removing one hydrogen from the intervening CH2 group...
NMR Spectroscopy of Aromatic Compounds
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent...
IR and UV–Vis Spectroscopy of Aldehydes and Ketones