Related Experiment Video
Updated: May 28, 2025

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
The association of metabolic positron emission tomography/computed tomography parameters with survival in small cell
Merve Ayık Türk1, Berna Kömürcüoğlu2, Nurşin Agüloğlu3
1From the Department of Pulmonology, University of Health Sciences Izmir Bozyaka Training and Research Hospital, Izmir, Turkey.
Background:
Small cell lung cancer (SCLC) is a lung malignancy with a poor prognosis and metastases at the time of diagnosis. There is limited experience using positron emission tomography/computed tomography (PET/CT) for SCLC diagnosis, staging, and follow-up.
Objective:
Investigate the survival effect of primary tumor standardized uptake value max (SUVmax), SUV mean, metabolic tumor volume (MTV), total lesion glucose (TLG), bone marrow SUV (BM), and bone marrow to liver ratio (BLR) in SCLC.
Design:
Retrospective.
Setting:
Single center in Turkey.
Patients And Methods:
Patients who were cyto/histologically diagnosed with SCLC and had PET/CT simultaneous with the diagnosis were included in the study.
Main Outcome Measures:
The effect of PET/CT parameters on overall survival (OS) and progression-free survival (PFS).
Sample Size:
304.
Results:
The 5-year OS median value was 14.62 months, and the 5-year PFS was 13.01 months. In Kaplan-Meier analysis, SUVmax, MTV, and TLG were statistically significant variables in OS (P=.03; P<.001; P<.001, respectively). MTV and TLG were significant in PFS (P<.001; P=.0003, respectively). In the multivariate analysis, MTV was an independent PET/CT parameter associated with OS (P=.003), stage of disease (P=.012), SUVmax (P=.003), MTV (P=.016), and TLG (P=.005) were significant variables in PFS.
Conclusion:
In our study, MTV was an independent parameter that can be used to predict survival in SCLC. Considering the effect of MTV, a metabolic PET/CT parameter on survival, it can be recommended for clinical use as a standard measure of evaluation in PET/CT reports, just like SUVmax.
Limitations:
The first limitation was the single-center and retrospective design of the study. Due to the retrospective design of the study, weight loss, performance status, and smoking history could not be obtained from every patient. Second, inaccurate registration of PET and CT images due to patient respiratory movements may affect measurements.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Cancer Survival Analysis
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET