A multimodal approach for sleep apnea detection: SpO2 and force sensitive sensors in a flexible 3D-printed wearable
Ayush Tiwari1, Manoj Kumar Baghel2, Vivek Kumar3
1Centre for Nanotechnology, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, 247667, India. ayush.ihub@sric.iitr.ac.in.
Abstract:
. The diagnosis of sleep apnea relies on the evaluation of polysomnography (PSG) recordings by experienced health monitoring practitioners. The labor-intensive nature of PSG and it's required complex instrumentation limit its widespread use across the general population. This research inquest offers a wearable health monitoring device in response to these challenges. The device incorporates a custom-fabricated force sensor resistor (FSR) seamlessly integrated with a microcontroller and pulse oximeter (SpO2) within a 3D-printed enclosure. Real-time respiratory and oxygen saturation data are wirelessly transmitted to a web-based interface for comprehensive and automated sleep apnea diagnosis. This prototype provides a comfortable, easy-to-use solution capable of accurate and automated diagnosis of sleep apnea. The sensor is fabricated by spray-coated silver ink finger electrodes, which were characterized by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDAX), confirming the presence of high silver content (97.6%) and low oxygen (2.4%), ensuring good electrical conductivity. Additionally, the designed finger electrode was simulated by COMSOL Multiphysics simulations software through repeated trials, suggesting a consistent and direct relationship between applied pressure and voltage output as per the Ohm's law. The sensor's voltage output varied linearly, with force (N) from 0 to 5 V and force (N) from 0 to 40 Newton. The COMSOL simulations uses electrostatic and moving mesh models matched with real-world experimental results further validated the sensor. The minimal non-linearity observed in practical scenarios proves the robustness of the sensor.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...