Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment
Published on: July 22, 2022
Wearable CNT/PAni/fabric piezoresistive sensor for continuous blood pressure monitoring
Milad Barati1, Alireza Nikfarjam1
1MEMS & NEMS Lab, Department of Microsystem and Photonics, School of Intelligent Systems Engineering, University of Tehran, Tehran, Iran.
Abstract:
Wearable pressure sensors with high sensitivity, fast response time, and low detection limit have great potential for blood pressure monitoring and early diagnosis of hypertension. This article introduces a piezoresistive pressure sensor based on carbon nanotubes (CNTs), polyaniline (PAni), and fabric (CNT/PAni/fabric) for health monitoring applications. This sensor is made by using two layers of linen fabric coated with CNT and PAni. These layers are placed on a polyester fabric substrate. One of the coated layers has a mesh structure, which increases the sensitivity of the sensor and lowers its detection limit. The CNT/PAni/fabric sensor has a high sensitivity of 2.035 kPa-1 at pressures from 0 to 0.2 kPa, a response time of 290 ms, and a detection limit of 1.5 Pa. These features make it suitable for measuring blood pressure. The results obtained by measuring blood pressure using the pulse transit time method on four people, compared with the values obtained using the digital sphygmomanometer, show a discrepancy ranging between 0.019% and 1.62%. Also, the average error and standard deviation for the sensor measurement in systolic and diastolic pressures are 0.56 ± 0.33 and 0.57 ± 0.46, respectively, which shows that measurement with this sensor can be an alternative to existing devices.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure